Vert-X 16 5V / 10 ... 90% Ub / Redundant

1631 7 36 2 2 5 1 02

Basic item

Technical datas

Housing

6 mm shaft D-shape; IP65 ( Standard )

Sensor principle

MH-C ( Standard )

Electrical angle

Electrical angle 360° ( Standard )

Power supply voltage

5 VDC ( Standard )

Output signal

10% to 90% operating voltage ( Standard )

Output characteristics

Redundant, crossed signal curves ( Optional )

Electrical connection

Ribbon cable, 6-pole ( Optional )

Length of wires/cable

20 cm ( Standard )


Features

  • Compact dimensions
  • Mounting tabs with metal inlets
  • Contactless measuring method
  • Long life
  • High accuracy of measurement
  • Use in cramped installation conditions
  • Full resolution and accuracy at programmed electrical angle

Files

Technical Plans

Vert-X_1601_1631.pdf

 

Technical Files

Vert-X_1601_1631.zip

 


Electrical Datas

Measuring range ° 0…360
Indep. linearity (typ.) % of measuring range ±0.3
Max. hysteresis ° 0.1
Resolution bit 12
Max. repeatability ° 0.1
Sample rate fast mode kHz (5)
Sample rate slow mode kHz 1.66
System propagation delay fast mode μs (800)
System propagation delay slow mode μs 4600
Max. temperature coefficient of output signal ppm/K 50
MTTFd / MTBF upon request
Power supply voltage VDC 5 (±10 %)
Current consumption without load (typ.) fast mode, per channel mA (14)
Current consumption without load (typ.) slow mode, per channel mA 9
Min. ohmic load at output kOhm 10
Max. capacitive load at output nF 100
Reverse polarity protection of power supply yes
Electrical connection redundant Ribbon cable, 6-pole
Cross section of single wires redundant mm² 0.09 (AWG28)

 


 

Mechanical Datas

Mechanical range ° 360 (continuous)
Protection rating IP54 / IP65
Max. starting torque at specified protection rating Ncm 0.5 / 3
Max. rotating speed rpm 120
Min. life movements 50 Mio.
Max. permitted axial shaft load N 10
Max. permitted radial shaft load N 10
Operating & storage temperature (with ribbon cable) °C -40 ... +105
EN 60068-2-6, vibration (Amax = 0.75 mm, f = 5–2,000 Hz) g 20
EN 60068-2-27, shock g 50

 


 

Standards

EN 55011, Emission (Cl. B)
EN 61000-4-2, ESD (contact discharge / air discharge) kV ±4 / ±8
EN 61000-4-3, Immission HF radiated (80–1000 MHz/1.4–2.7 GHz) V/m 30
EN 61000-4-4, Burst (on all lines) kV ±1
EN 61000-4-5, Surge (lines to ground) kV ±1
EN 61000-4-6, Immission HF conducted (0.15–80 MHz) Vemf 10
EN 61000-4-8, Immission magnetic field (50 Hz) A/m 300
Insulation resistance (500 VDC, 1 bar, 2s) GOhm 20
Dielectric strength (VAC, 50 Hz, 1 min, 1 bar) kV 1

 


 

Options

Custom shaft design
Custom cable/wires
Interface x% to y% operating voltage (within 2% to 98% operating voltage)
Sample rate in fast mode
Special electrical angle between 30 and 360° (ex factory)

Contact