Vert-X TI 5V / 10...90% Ub / Redundant

TI5 H 7 36 2 2 4 S 06

Technical datas

Mechanical version

Mounting tab housing ( Standard )

Shaft

Lever ( Standard )

Sensor principle

MH-C ( Standard )

Electrical angle

Electrical angle 360° ( Standard )

Power supply voltage

5 VDC ( Standard )

Output signal

10% to 90% operating voltage ( Standard )

Output characteristics

Redundant, positive gradient CCW ( Optional )

Electrical connection

Connector ( Standard )

Definition of the connector

1x connector, 6-pole ( Standard )


Features

  • Compact dimensions
  • Contactless measuring method
  • Long life
  • High measurement accuracy
  • Full resolution and accuracy at programmed electrical angle

 

 

Files

Technical Plans

Vert-X_TI5H.pdf

 

Technical Files

[Translate to English:]

 


Electrical Datas

Measuring range ° 0…360
Indep. linearity (@360°) % ±0.5
Max. hysteresis ° 0.1
Resolution bit 12
Max. repeatability ° 0.1
Sample rate fast mode kHz (5)
Sample rate slow mode kHz 1.66
System propagation delay fast mode μs (800)
System propagation delay slow mode μs 4600
Max. temperature coefficient of output signal ppm/K 50
MTTFd / MTBF upon request
Power supply voltage VDC 5 (±10%)
Current consumption without load (typ.) fast mode, per channel mA (14)
Current consumption without load (typ.) slow mode, per channel mA 9
Min. ohmic load at output kOhm 10
Max. capacitive load at output nF 100
Reverse polarity protection of power supply yes
Electrical connection Deutsch DTM04 connector, 6-pole

 


 

Mechanical Datas

Mechanical range ° 360 (continuous)
Protection rating IP67
Max. rotating speed rpm 120
Min. life movements 50 Mio no limitation
Max. permitted axial shaft load N 10
Max. permitted radial shaft load N 10
Operating & storage temperature °C -40 ... +85
EN 60068-2-6, vibration (Amax = 0.75 mm, f = 5–2,000 Hz) g 20
EN 60068-2-27, shock g 50

 


 

Standards

EN 55011, Emission (Cl. B)
EN 61000-4-2, ESD (contact discharge / air discharge) kV ±4 / ±8
EN 61000-4-3, Immission HF radiated (80–1000 MHz/1.4–2.7 GHz) V/m 30
EN 61000-4-4, Burst (on all lines) kV ±1
EN 61000-4-5, Surge (lines to ground) kV ±1
EN 61000-4-6, Immission HF conducted (0.15–80 MHz) Vemf 10
EN 61000-4-8, Immission magnetic field (50 Hz) A/m 300
Insulation resistance (500 VDC, 1 bar, 2s) GOhm 20
Dielectric strength (VAC, 50 Hz, 1 min, 1 bar) kV 1

 


 

Options

Custom connector
Custom shaft design
Interface x% to y% operating voltage (within 2% to 98% operating voltage)
Sample rate in fast mode
Special electrical angle between 30 and 360° (ex factory)

Contact