Vert-X 31E 8 ... 35V / Inkremental Open collector

31E5 b D 36 1 7 7 9 02

Technical datas

Mechanical version

Magnetic actuator type 5 ( Standard )

Mounting hole

Through-hole ø4.4 mm with counterbore ø7.4 mm ( Optional )

Sensor principle

MH-S ( Standard )

Electrical angle

Electrical angle 360° ( Standard )

Power supply voltage

24 VDC ( Standard )

Output signal

Incremental ( Standard )

Output characteristics / output driver

Open collector (A,B,Z) ( Standard )

Electrical connection

Special cable ( Optional )

Length of cable

1.0 m (cable) ( Standard )


Features

  • High protection rating IP68
  • Compact dimensions
  • Very quick, non-contacting measuring method
  • Very long life
  • Can be used in harsh environments (humidity, dampness, dust, vibrations, etc.)
  • Several possible resolutions
  • Low temperature coefficient of output signal

Electrical Datas

Measuring range ° 0…360
Indep. linearity (without misalignment) % ±0.5
Indep. linearity (with permitted misalignment @ 360°) % ±1
Max. hysteresis ° 0.5
Resolution bit 256 (1-1024)
Max. repeatability ° 0.1
Max. temperature coefficient of output signal ppm/K 50
MTTFd / MTBF upon request
Power supply voltage VDC 8 … 35
Current consumption without load (typ.) mA 20
Max. latency μs 10
Max. current at output mA 30
Max. voltage at output VDC 35
Reverse polarity protection of power supply yes
Electrical connection (A;B) Round cable, 4-pole
Electrical connection (A;B;Z) Round cable, 6-pole
Cross section of single wires (A;B) mm² 0.35 (AWG22)
Cross section of single wires (A;B;Z) mm2 0.25 (AWG24)
Redundancy possible no

 


 

Mechanical Datas

Mechanical range ° 360 (continuous)
Protection rating IP68
Min. life movements no limitation
Operating & storage temperature °C -40…+85
EN 60068-2-6, vibration (Amax = 0.75 mm, f = 5–2,000 Hz) g 50
EN 60068-2-27, shock g 200

 


 

Standards

EN 55011, Emission (Cl. B)
EN 61000-4-2, ESD (contact discharge / air discharge) kV ±4 / ±8
EN 61000-4-3, Immission HF radiated (80–1000 MHz/1.4–2.7 GHz) V/m 30
EN 61000-4-4, Burst (on all lines) kV ±1
EN 61000-4-5, Surge (lines to ground) kV ±1
EN 61000-4-6, Immission HF conducted (0.15–80 MHz) Vemf 10
EN 61000-4-8, Immission magnetic field (50 Hz) A/m 300
Insulation resistance (500 VDC, 1 bar, 2s) GOhm 20