Vert-X 48E 11 ... 35V / 4 - 20mA / Single

48E5 7 36 1 5 2 9 99

Technical datas

Mechanical version

Magnetic actuator type 5 ( Optional )

Sensor principle

MH-C ( Standard )

Electrical angle

Electrical angle 360° ( Standard )

Power supply voltage

24 VDC ( Standard )

Output signal

4 mA to 20 mA ( Standard )

Output characteristics

Single, positive gradient CCW ( Optional )

Electrical connection

Special cable ( Optional )

Length of cable

Special length ( Optional )


Features

  • High protection rating IP68/IP69K
  • Very robust design
  • Non-contacting measuring method
  • Very long life
  • High measurement accuracy
  • Can be used in harsh environments (humidity, dampness, oil, dust, vibrations, etc.)
  • Full resolution and accuracy at programmed electrical angle
  • Magnetic loss detection (with safety flag)

 

Features MH-C

  • Resolution 12 bit
  • Full redundancy possible
  • Lower price than MH-C2

Electrical Datas

Measuring range ° 0…360
Indep. linearity (typ.) % of measuring range ±0.3
Max. hysteresis ° 0.1
Resolution bit 12
Max. repeatability ° 0.1
Sample rate fast mode kHz (5)
Sample rate slow mode kHz 1.66
System propagation delay fast mode μs (800)
System propagation delay slow mode μs 4600
Max. temperature coefficient of output signal ppm/K 100
MTTFd / MTBF upon request
Power supply voltage (ohmic load at output = 0–0.5 kOhm) VDC 16...35
Power supply voltage (ohmic load at output = 0–0.25 kOhm) VDC 11...35
Current consumption without load (typ.) fast mode, per channel mA (19)
Current consumption without load (typ.) slow mode, per channel mA 14
Max. capacitive load at output nF 100
Reverse polarity protection of power supply yes
Electrical connection (s = shielded) Round cable, 3-pole, s
Cross section of single wires mm² 0.56 (AWG20)
Redundancy possible yes

 


 

Mechanical Datas

Mechanical range ° 360 (continuous)
Protection rating IP68 / IP69K
Min. life movements no limitation
Operating & storage temperature °C -40 ... +85
EN 60068-2-6, vibration (Amax = 0.75 mm, f = 5–2,000 Hz) g 50
EN 60068-2-27, shock g 200

 


 

Standards

EN 55011, Emission (Cl. B)
EN 61000-4-2, ESD (contact discharge / air discharge) kV ±4 / ±8
EN 61000-4-3, Immission HF radiated (80–1000 MHz/1.4–2.7 GHz) V/m 30
EN 61000-4-4, Burst (on all lines) kV ±1
EN 61000-4-5, Surge (lines to ground) kV ±1
EN 61000-4-6, Immission HF conducted (0.15–80 MHz) Vemf 12
EN 61000-4-8, Immission magnetic field (50 Hz) A/m 300
Insulation resistance (500 VDC, 1 bar, 2s) GOhm 20
Dielectric strength (VAC, 50 Hz, 1 min, 1 bar) kV 1

 


 

Options

Custom modification of housing
Custom cable
Custom magnetic actuator
Sample rate in fast mode
Switch functions TTL (max. 2)
Special electrical angle between 30 and 360° (ex factory)
Extended operating range, axial (without safety flag)