Vert-X 32E 8 ... 35V / CANopen / Single

32E5 b 8 36 1 3 3 6 99

Technical datas

Mechanical version

Magnetic actuator type 5 ( Optional )

Mounting hole

Through-hole ø 4.4 mm with counter bore ø 8 mm/label side ( Standard )

Sensor principle

MH-C2 ( Standard )

Electrical angle

Electrical angle 360° ( Standard )

Power supply voltage

24 VDC ( Standard )

Output signal

CANopen Encoder Profile 406 (C2) ( Standard )

CAN characteristics

CAN high In; CAN high Out; CAN low In; CAN low Out ( Optional )

Electrical connection

Round cable, 6-pole ( Optional )

Length of cable

Special length ( Optional )


Features

  • CiA approved
  • Non-contacting measuring method
  • High protection rating IP68/IP69K
  • Very long life
  • High measurement accuracy
  • Can be used in harsh environments (humidity, dampness, dust, vibrations, etc.)
  • Magnetic loss detection (with safety flag)

Electrical Datas

Measuring range ° 0…360
Indep. linearity (typ.) % of measuring range ±0.3
Max. hysteresis ° 0.1
Resolution bit 16
Max. repeatability ° 0.1
Sample rate kHz 0.5
Max. temperature coefficient of output signal ppm/K 25
MTTFd / MTBF upon request
Power supply voltage VDC 8 ... 35
Current consumption without bus load (typ.), per channel mA 30
Reverse polarity protection of power supply yes
Electrical connection Round cable, s
Cross section of single wires mm² 0.34 (AWG 22)
Bus interface ISO/DIS 11898-2
CANopen communication according to CiA Standard DS-301 Rev. 4.02
Device profile DS-406, Rev. 3.1, Encoder class C2
Default node ID 16 (programmable 1 to 127)
Default bitrate kBit/s 125

 


 

Mechanical Datas

Mechanical range ° 360 (continuous)
Protection rating IP68/IP69K
Min. life movements no limitation
Operating & storage temperature °C -40…+85
EN 60068-2-6, vibration (Amax = 0.75 mm, f = 5–2,000 Hz) g 20
EN 60068-2-27, shock g 50

 


 

Standards

EN 55011, Emission (Cl. B)
EN 61000-4-2, ESD (contact discharge / air discharge) kV ±4 / ±8
EN 61000-4-3, Immission HF radiated (80–1000 MHz/1.4–2.7 GHz) V/m 30
EN 61000-4-4, Burst (on all lines) kV ±1
EN 61000-4-5, Surge (lines to ground) kV ±1
EN 61000-4-6, Immission HF conducted (0.15–80 MHz) Vemf 10
EN 61000-4-8, Immission magnetic field (50 Hz) A/m 300
Insulation resistance (500 VDC, 1 bar, 2s) GOhm 20
Dielectric strength (VAC, 50 Hz, 1 min, 1 bar) kV 1

 


 

Options

Custom modification of housing
Custom cable
Custom magnetic actuator
Sample rate in fast mode
Special electrical angle between 30 and 360° (ex factory)
Full redundancy possible
Extended operating range, axial (without safety flag)

Contact