Vert-X 32E 8 ... 35V / Open collector

32E5 d D 36 1 7 7 6 99

Technical datas

Mechanical version

Magnetic actuator type 5 ( Optional )

Mounting hole

Through-hole ø 4.4 mm with counter bore ø 8 mm/magnetic actuator side ( Optional )

Sensor principle

MH-S ( Standard )

Electrical angle

Electrical angle 360° ( Standard )

Power supply voltage

24 VDC ( Standard )

Output signal

Incremental ( Standard )

Output characteristics / output driver

Open collector (A,B,Z) ( Standard )

Electrical connection

Cable, 6-pole ( Standard )

Length of cable

Special length ( Optional )


Features

  • Bearingless incremental Encoder
  • Resolution ex factory free programmable from 1ppr to max. 1024 ppr
  • Non-contact, wear-free sensing system with high permissible installation tolerances
  • High protection class IP68/ IP69K
  • Compact dimensions
  • Very fast, non-contacting measuring method
  • Very long life
  • Applications under adverse ambient conditions possible (humidity, dampness, dust, vibrations etc.)
  • Low temperaturecoefficient of the output signal

Electrical Datas

Measuring range ° 0…360
Indep. linearity (without misalignment) % ±0.5
Indep. linearity (with permitted misalignment @ 360°) % ±1
Max. hysteresis ° 0.5
Resolution bit 256 (1-1024)
Max. repeatability ° 0.1
Max. temperature coefficient of output signal ppm/K 50
MTTFd / MTBF upon request
Power supply voltage VDC 8 ... 35
Current consumption without load (typ.) mA 20
Max. latency μs 10
Max. current at output mA 30
Max. voltage at output VDC 35
Reverse polarity protection of power supply no
Electrical connection (A;B) Round cable, 4-pole
Electrical connection (A;B;Z) Round cable, 6-pole
Cross section of single wires (A;B) mm² 0.35 (AWG22)
Cross section of single wires (A;B;Z) mm2 0.25 (AWG24)
Redundancy possible no

 


 

Mechanical Datas

Mechanical range ° 360 (continuous)
Protection rating IP68/IP69K
Min. life movements no limitation
Operating & storage temperature °C -40…+85
EN 60068-2-6, vibration (Amax = 0.75 mm, f = 5–2,000 Hz) g 20
EN 60068-2-27, shock g 50

 


 

Standards

EN 55011, Emission (Cl. B)
EN 61000-4-2, ESD (contact discharge / air discharge) kV ±4 / ±8
EN 61000-4-3, Immission HF radiated (80–1000 MHz/1.4–2.7 GHz) V/m 30
EN 61000-4-4, Burst (on all lines) kV ±1
EN 61000-4-5, Surge (lines to ground) kV ±1
EN 61000-4-6, Immission HF conducted (0.15–80 MHz) Vemf 10
EN 61000-4-8, Immission magnetic field (50 Hz) A/m 300
Insulation resistance (500 VDC, 1 bar, 2s) GOhm 20
Dielectric strength (VAC, 50 Hz, 1 min, 1 bar) kV 1

 


 

Options

Custom cable
Custom magnetic actuator
Custom output driver
Custom resolution (1-1024 ppr)
Higher speed on request

Contact