Vert-X 22E 11 ... 35V / 4 - 20mA / Single

22E1 8 36 1 5 1 4 05

Technical datas

Mechanical version

Magnetic actuator type 1 ( Optional )

Sensor principle

MH-C2 ( Standard )

Electrical angle

Electrical angle 360° ( Standard )

Power supply voltage

24 VDC ( Standard )

Output signal

4 mA to 20 mA ( Standard )

Output characteristics

Single, positive gradient CW ( Standard )

Electrical connection

Round cable, 3-pole ( Optional )

Length of wires / cable / ribbon cable

50 cm (wires) ( Standard )


*Switching outputs / Please define number (max. 127), position and width of pulses.

MH-C2 features

  • Resolution 14 bit
  • Index point(s), direction of rotation and angle can be set and programmed by customer (optional)

Electrical Datas

Measuring range ° 0…360
Indep. linearity (typ.) % of measuring range ±0.1
Max. hysteresis ° 0.1
Resolution bit 14
Max. repeatability ° 0.1
Sample rate fast mode kHz (2)
Sample rate slow mode kHz 0.5
System propagation delay fast mode μs (800)
System propagation delay slow mode μs 2500
Max. temperature coefficient of output signal ppm/K 100
MTTFd / MTBF upon request
Power supply voltage (ohmic load at output = 0–0.5 kOhm) VDC 16 ... 35
Power supply voltage (ohmic load at output = 0–0.25 kOhm) VDC 11 ... 35
Current consumption without load (typ.) fast mode, per channel mA (20)
Current consumption without load (typ.) slow mode, per channel mA 15
Ohmic load at output kΩ / kOhm 0 ... 0.5
Max. capacitive load at output nF 100
Reverse polarity protection of power supply yes
Electrical connection axial Wires (3x)
Electrical connection radial Round cable, 3-pole
Cross section of single wires mm² 0.25 (AWG24)
Redundancy possible no

 


 

Mechanical Datas

Mechanical range ° 360 (continuous)
Protection rating IP68
Min. life movements no limitation
Operating & storage temperature °C -40 ... +85
EN 60068-2-6, vibration (Amax = 0.75 mm, f = 5–2,000 Hz) g 50
EN 60068-2-27, shock g 200

 


 

Standards

EN 55011, Emission (Cl. B)
EN 61000-4-2, ESD (contact discharge / air discharge) kV ±4 / ±8
EN 61000-4-3, Immission HF radiated (80–1000 MHz/1.4–2.7 GHz) V/m 30
EN 61000-4-4, Burst (on all lines) kV ±1
EN 61000-4-5, Surge (lines to ground) kV ±1
EN 61000-4-6, Immission HF conducted (0.15–80 MHz) Vemf 10
EN 61000-4-8, Immission magnetic field (50 Hz) A/m 300
Insulation resistance (500 VDC, 1 bar, 2s) GOhm 20
Dielectric strength (VAC, 50 Hz, 1 min, 1 bar) kV 1

 


 

Options

Custom modification of housing
Custom cable/wires
Custom magnetic actuator
Sample rate in fast mode
Switch functions TTL (max. 2)
Special characteristic curve
Special electrical angle between 30 and 360° (ex factory)
Electrical angle programmable (software)
Start and end point settable (additional wires)
Direction of rotation CW/CCW settable/programmable (additional wires or software)
Index point settable/programmable (additional wires or software)

Contact