Vert-X 22E 8 ... 35V / 0.5 - 4.5V / Redundant
22E1 7 36 1 2 3 9 05
Technical datas
MH-C features
- Resolution 12 bit
-
Full redundancy possible
- Lower price than MH-C2
Files
Technical Plans
Vert-X_22E1_axial.pdfVert-X_22E1_radial.pdf
[Translate to English:]
Technical Files
[Translate to English:]
accessories
Clip_Vert-X22E.pdf
Electrical Datas
Measuring range | ° | 0…360 |
Indep. linearity (typ.) | % of measuring range | ±0.3 |
Max. hysteresis | ° | 0.1 |
Resolution | bit | 12 |
Max. repeatability | ° | 0.1 |
Sample rate fast mode | kHz | (5) |
Sample rate slow mode | kHz | 1.66 |
System propagation delay fast mode | μs | (800) |
System propagation delay slow mode | μs | 4600 |
Max. temperature coefficient of output signal | ppm/K | 100 |
MTTFd / MTBF | upon request | |
Power supply voltage | VDC | 8 ... 35 |
Current consumption without load (typ.) fast mode, per channel | mA | (19) |
Current consumption without load (typ.) slow mode, per channel | mA | 14 |
Min. ohmic load at output | kOhm | 10 |
Max. capacitive load at output | nF | 100 |
Reverse polarity protection of power supply | yes | |
Electrical connection redundant axial | Ribbon cable, 6-pole | |
Electrical connection redundant radial | Round cable, 6-pole | |
Cross section of single wires redundant axial | mm2 | 0.09 (AWG28) |
Cross section of single wires redundant radial | mm2 | 0.25 (AWG24) |
Mechanical Datas
Mechanical range | ° | 360 (continuous) |
Protection rating | IP68 | |
Min. life | movements | no limitation |
Operating & storage temperature | °C | -40 ... +85 |
EN 60068-2-6, vibration (Amax = 0.75 mm, f = 5–2,000 Hz) | g | 50 |
EN 60068-2-27, shock | g | 200 |
Standards
EN 55011, Emission (Cl. B) | ||
EN 61000-4-2, ESD (contact discharge / air discharge) | kV | ±4 / ±8 |
EN 61000-4-3, Immission HF radiated (80–1000 MHz/1.4–2.7 GHz) | V/m | 30 |
EN 61000-4-4, Burst (on all lines) | kV | ±1 |
EN 61000-4-5, Surge (lines to ground) | kV | ±1 |
EN 61000-4-6, Immission HF conducted (0.15–80 MHz) | Vemf | 10 |
EN 61000-4-8, Immission magnetic field (50 Hz) | A/m | 300 |
Insulation resistance (500 VDC, 1 bar, 2s) | GOhm | 20 |
Dielectric strength (VAC, 50 Hz, 1 min, 1 bar) | kV | 1 |
Options
Custom modification of housing |
Custom cable/wires |
Custom magnetic actuator |
Sample rate in fast mode |
Switch functions TTL (max. 2) |
Special electrical angle between 30 and 360° (ex factory) |