Vert-X 22 5V / PWM / Single

2211 7 36 2 4 1 9 99

Technical datas

Mechanical version

Synchro flange size 9; 6 mm shaft, D-shape; IP54 ( Standard )

Sensor principle

MH-C ( Standard )

Electrical angle

Electrical angle 360° ( Standard )

Power supply voltage

5 VDC ( Standard )

Output signal

PWM ( Standard )

Output characteristics

Single, positive gradient CW ( Standard )

Electrical connection

Special cable ( Optional )

Length of cable

Special length ( Optional )


Features

  • Robust design, sealed stainless steel housing
  • Contactless measuring method
  • Long life
  • High accuracy of measurement
  • Applications under adverse ambient conditions possible (humidity, dampness, dust, vibrations etc.)
  • Full resolution and accuracy at programmed electrical angle

Files

Technical Plans

Vert-X_2202_2232.pdf

 

Technical Files

Vert-X_2202_2232.zip

 

accessories

Fixation_clip_Vert-X_21xx_22xx.zip

 


Electrical Datas

Measuring range ° 0…360
Indep. linearity (typ.) % of measuring range ±0.3
Max. hysteresis ° 0.1
Resolution bit 12
Max. repeatability ° 0.1
Sample rate fast mode kHz (5)
Sample rate slow mode kHz 1.66
System propagation delay fast mode μs (800)
System propagation delay slow mode μs 4600
Max. temperature coefficient of output signal ppm/K 25
MTTFd / MTBF upon request
Power supply voltage VDC 5 (±10%)
Current consumption without load (typ.) fast mode, per channel mA (14)
Current consumption without load (typ.) slow mode, per channel mA 9
Min. ohmic load at output kOhm 10
Max. capacitive load at output nF 1
PWM frequency Hz 855 (±20%)
Reverse polarity protection of power supply yes
Electrical connection (s = shielded) Round cable, 3-pole, s
Cross section of single wires mm² 0.25 (AWG24)
Redundancy possible yes

 


 

Mechanical Datas

Mechanical range ° 360 (continuous)
Protection rating IP54 / IP67
Max. starting torque at specified protection rating Ncm 0.5 / 3
Max. rotating speed rpm 6000
Min. life movements 360 Mio.
Max. permitted axial shaft load N 100
Max. permitted radial shaft load N 50
Operating & storage temperature °C -40 ... +85
EN 60068-2-6, vibration (Amax = 0.75 mm, f = 5–2,000 Hz) g 20
EN 60068-2-27, shock g 50

 


 

Standards

EN 55011, Emission (Cl. B)
EN 61000-4-2, ESD (contact discharge / air discharge) kV ±4 / ±8
EN 61000-4-3, Immission HF radiated (80–1000 MHz/1.4–2.7 GHz) V/m 30
EN 61000-4-4, Burst (on all lines) kV ±1
EN 61000-4-5, Surge (lines to ground) kV ±1
EN 61000-4-6, Immission HF conducted (0.15–80 MHz) Vemf 10
EN 61000-4-8, Immission magnetic field (50 Hz) A/m 300
Insulation resistance (500 VDC, 1 bar, 2s) GOhm 20
Dielectric strength (VAC, 50 Hz, 1 min, 1 bar) kV 1

 


 

Options

Custom shaft design
Custom modification of housing
Custom cable
Sample rate in fast mode
Switch functions TTL (max. 2)
Special electrical angle between 30 and 360° (ex factory)